; Configuration file for Duet WiFi (firmware version 2.03)
; Configuration file for Duet WiFi (firmware version 2.03)
; executed by the firmware on start-up
; executed by the firmware on start-up
;
;
; generated by RepRapFirmware Configuration Tool v2.1.8 on Sat Apr 04 2020 19:27:02 GMT+0200 (Ora legale dell’Europa centrale)
; generated by RepRapFirmware Configuration Tool v3.4.1 on Sat Apr 26 2025 19:13:09 GMT+0200 (Ora legale dell’Europa centrale)


; General preferences
; General preferences
M575 P1 S1 B57600 ; enable support for PanelDue
G90 ; send absolute coordinates...
G90 ; send absolute coordinates...
M83 ; ...but relative extruder moves
M83 ; ...but relative extruder moves
M550 P"My Printer EUGENIO" ; set printer name
M550 P"BAY PRINT EUGENIO" ; set printer name


; Network
; Network
M552 P192.168.1.18 S1 ; enable network and set IP address
M552 P192.168.1.18 S1 ; enable network and set IP address
M553 P255.255.255.0 ; set netmask
M553 P255.255.255.0 ; set netmask
M554 P192.168.1.254 ; set gateway
M554 P192.168.1.254 ; set gateway
M586 P0 S1 ; enable HTTP
M586 P0 S1 ; enable HTTP
M586 P1 S0 ; disable FTP
M586 P1 S0 ; disable FTP
M586 P2 S0 ; disable Telnet
M586 P2 S0 ; disable Telnet


; Drives
; Drives
M569 P0 S0 ; physical drive 0 goes backwards
M569 P0 S0 ; physical drive 0 goes backwards
M569 P1 S0 ; physical drive 1 goes backwards
M569 P1 S0 ; physical drive 1 goes backwards
M569 P2 S0 ; physical drive 2 goes backwards
M569 P2 S0 ; physical drive 2 goes backwards
M569 P3 S0 ; physical drive 3 goes backwards
M569 P3 S1 ; physical drive 3 goes forwards
M584 X0 Y1 Z2 E3 ; set drive mapping
M584 X0 Y1 Z2 E3 ; set drive mapping
M350 X32 Y32 I0 ; configure microstepping without interpolation
M350 X32 Y32 I0 ; configure microstepping without interpolation
M350 Z16 E16 I1 ; configure microstepping with interpolation
M350 Z16 E16 I1 ; configure microstepping with interpolation
M92 X160.00 Y160.00 Z4000.00 E420.00 ; set steps per mm
M92 X160.00 Y160.00 Z400.00 E84.88 ; set steps per mm
M566 X900.00 Y900.00 Z12.00 E120.00 ; set maximum instantaneous speed changes (mm/min)
M566 X12000.00 Y12000.00 Z180.00 E2400.00 ; set maximum instantaneous speed changes (mm/min)
M203 X6000.00 Y6000.00 Z180.00 E1200.00 ; set maximum speeds (mm/min)
M203 X36000.00 Y36000.00 Z240.00 E2400.00 ; set maximum speeds (mm/min)
M201 X500.00 Y500.00 Z20.00 E250.00 ; set accelerations (mm/s^2)
M201 X1500.00 Y1500.00 Z30.00 E1500.00 ; set accelerations (mm/s^2)
M906 X1300 Y1300 Z800 E800 I30 ; set motor currents (mA) and motor idle factor in per cent
M906 X1300 Y1300 Z800 E800 I30 ; set motor currents (mA) and motor idle factor in per cent
M84 S30 ; Set idle timeout
M84 S30 ; Set idle timeout


; Axis Limits
; Axis Limits
M208 X-10 Y-10 Z0 S1 ; set axis minima
M208 X-10 Y-10 Z0 S1 ; set axis minima
M208 X310 Y310 Z450 S0 ; set axis maxima
M208 X310 Y310 Z450 S0 ; set axis maxima


; Endstops
; Endstops
M574 X1 Y1 Z1 S0 ; set active low and disabled endstops
M574 X1 Y1 S0 ; set active low and disabled endstops
M574 Z1 S2 ; set endstops controlled by probe


; Z-Probe
; Z-Probe
M558 P0 H5 F120 T6000 ; disable Z probe but set dive height, probe speed and travel speed
M307 H3 A-1 C-1 D-1 ; disable heater on PWM channel for BLTouch
M557 X20:290 Y10:290 S20 ; define mesh grid
M558 P9 H15 F120 T6000 ; set Z probe type to bltouch and the dive height + speeds
M558 H30 ;*** Remove this line after delta calibration has been done and new delta parameters have been saved
G31 P500 X220 Y165 Z3.65 ; set Z probe trigger value, offset and trigger height
M557 X-7:285 Y30:290 S40 ; define mesh grid


; Heaters
; Heaters
M307 H0 B0 S1.00 ; disable bang-bang mode for the bed heater and set PWM limit
M305 P0 T100000 B4138 R4700 ; set thermistor + ADC parameters for heater 0
M305 P0 T100000 B4138 R4700 ; set thermistor + ADC parameters for heater 0
M143 H0 S120 ; set temperature limit for heater 0 to 120C
M143 H0 S120 ; set temperature limit for heater 0 to 120C
M305 P1 T100000 B4138 R4700 ; set thermistor + ADC parameters for heater 1
M305 P1 T100000 B4681 C6.463940e-8 R4700 ; set thermistor + ADC parameters for heater 1
M143 H1 S280 ; set temperature limit for heater 1 to 280C
M143 H1 S300 ; set temperature limit for heater 1 to 300C


; Fans
; Fans
M106 P0 S0 I0 F500 H-1 ; set fan 0 value, PWM signal inversion and frequency. Thermostatic control is turned off
M106 P0 S0 I0 F500 H1 T45 ; set fan 0 value, PWM signal inversion and frequency. Thermostatic control is turned on
M106 P1 S1 I0 F500 H1 T45 ; set fan 1 value, PWM signal inversion and frequency. Thermostatic control is turned on
M106 P1 S1 I0 F500 H1 T45 ; set fan 1 value, PWM signal inversion and frequency. Thermostatic control is turned on


; Tools
; Tools
M563 P0 S"E0" D0 H1 F0 ; define tool 0
M563 P0 D0 H1 F0 ; define tool 0
G10 P0 X0 Y0 Z0 ; set tool 0 axis offsets
G10 P0 X0 Y0 Z0 ; set tool 0 axis offsets
G10 P0 R0 S0 ; set initial tool 0 active and standby temperatures to 0C
G10 P0 R0 S0 ; set initial tool 0 active and standby temperatures to 0C


; Custom settings
; Custom settings are not defined
M92 E 95.245


; Miscellaneous
; Miscellaneous
M911 S18 R23 P"M913 X0 Y0 G91 M83 G1 Z3 E-5 F1000" ; set voltage thresholds and actions to run on power loss
M501 ; load saved parameters from non-volatile memory
M911 S21 R22 P"M913 X0 Y0 G91 M83 G1 Z3 E-5 F1000" ; set voltage thresholds and actions to run on power loss